Reproducibility of risk figures in 2nd-trimester maternal serum screening for down syndrome: comparison of 2 laboratories.

Benn PA, Makowski GS, Egan JF, Wright D

Division of Human Genetics, Department of Genetics and Developmental Biology, University of Connecticut Health Center, Farmington, CT 06030-6140, USA. Benn@nso1.uchc.edu

BACKGROUND: Analytical error affects 2nd-trimester maternal serum screening for Down syndrome risk estimation. We analyzed the between-laboratory reproducibility of risk estimates from 2 laboratories. METHODS: Laboratory 1 used Bayer ACS180 immunoassays for alpha-fetoprotein (AFP) and human chorionic gonadotropin (hCG), Diagnostic Systems Laboratories (DSL) RIA for unconjugated estriol (uE3), and DSL enzyme immunoassay for inhibin-A (INH-A). Laboratory 2 used Beckman immunoassays for AFP, hCG, and uE3, and DSL enzyme immunoassay for INH-A. Analyte medians were separately established for each laboratory. We used the same computational algorithm for all risk calculations, and we used Monte Carlo methods for computer modeling. RESULTS: For 462 samples tested, risk figures from the 2 laboratories differed >2-fold for 44.7%, >5-fold for 7.1%, and >10-fold for 1.7%. Between-laboratory differences in analytes were greatest for uE3 and INH-A. The screen-positive rates were 9.3% for laboratory 1 and 11.5% for laboratory 2, with a significant difference in the patients identified as screen-positive vs screen-negative (McNemar test, P<0.001). Computer modeling confirmed the large between-laboratory risk differences. CONCLUSION: Differences in performance of assays and laboratory procedures can have a large effect on patient-specific risks. Screening laboratories should minimize test imprecision and ensure that each assay performs in a manner similar to that assumed in the risk computational algorithm.

Published 27 October 2006 in Clin Chem, 52(11): 2087-94.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2004-2008 Down Syndrome Research Today. All Rights Reserved.



Down Syndrome Research Today Archive:

Volume 1 (2004)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2005)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)



Down Syndrome Books

Learn to Move, Move to Learn: Sensorimotor Early Childhood Activity Themes

Learn to Move, Move to Learn: Sensorimotor Early Childhood Activity Themes